AS NZS 5263.1.7:2020 pdf free
AS NZS 5263.1.7:2020 pdf free.Gas appliances Part 1.7: Domestic outdoor gas cooking appliances
When tested in accordance with Test Method ZA.1 the leakage rate shall not exceed 1 mL/min when the appliance is subjected to an inlet gas pressure of 1.5 times the rated working pressure or 14 kPa,whichever is greater, for一
(a) the gas train in the state received by the end user or installer and prior to any modification or assembly required for the attachment of any accessories; and
(b) the fully assembled gas train after performing the modifications and assembly required to attach any accessories.
The total determined gas consumption of all burners, including accessory burners, operating together in accordance with the manufacturer’s instructions, shall be within 20 % of the sum total of the nominal gas consumption of each operated burner. Testing shall be in accordance with Test Method ZA.2.
An appliance designed for manual ignition shall be readily lit by means of a 40 mm match. In the case of multiple burner appliances, ignition by match of one burner shall be acceptable, provided that cross lighting means ensure safe and effective ignition of part of or the complete burner system.
NOTE The provision of a permanently attached device to facilitate the use of a match is acceptable.
Appliances and their associated side burners(s) and other accessory burner(s) shall conform to the requirements of this Section when supplied with the test gases and under the limiting conditions specified in each clause, with the following exceptions:
(a) Appliances intended for use with natural gas may be tested using available natural gas but in the case of dispute or borderline results test gas“N” shall be used.
(b) Appliances intended for use with town gas may be tested using available town gas but in the case of dispute or borderline results test gas “D”shall be used.
When tested in accordance with Test Method ZB.1, the CO/CO2 ratio of the combustion products of any independent surface combustion burner shall not exceed 0.02, 5 min after ignition, with the appliance operating at the limiting condition specified in Table 4.2.AS NZS 5263.1.7 pdf free download.