AS NZS 60335.2.43:2018 pdf free
AS NZS 60335.2.43:2018 pdf free.Household and similar electrical appliances – Safety
The installation instructions for fixed towel rails shall include the substance of the following:
WARNING: In order to avoid a hazard for very young children, this appliance should be installed so that the lowest heated rail is at least 600 mm above the floor.
The instructions for fixed towel rails likely to be used in a bathroom shall state that the towel rail is to be installed so that switches and other controls cannot be touched by a person in the bath or shower. This instruction is not necessary if the towel rail is at least IPX4.
If the temperature rise limits are exceeded in appliances incorporating motors, transformers or electronic circuits, and the power input is lower than the rated power input, the test is repeated with the appliance supplied at 1,06 times rated voltage.
The temperature rise at the air outlet of clothes dryers intended for drying footwear or gloves shall not exceed the limits of Table 3 for handles held for short periods only.
The temperature rise limits of motors, transformers and components of electronic circuits,including parts directly influenced by them, may be exceeded when the appliance is operated at 1,15 times rated power input.
For appliances having a heated surface that supports the textiles, eight layers of textiles are used. For appliances in which the textiles are dried by a warm airflow, two layers of textiles are placed on the heating element guard or over the air inlet if the heating unit is located above the textiles.
The test is carried out with the textiles completely covering the guard or air inlet and then with the textiles covering 80 % of the area of the guard or air inlet, taking into account different positions of the textiles in order to find the most unfavourable condition.AS NZS 60335.2.43 pdf free download.